Cosmed Driver
Products
COSMED Quark C12x/T12x, Tango M2 Interface Notes Page 4 of 4 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. Remove the bladder and microphone from the outer shell of. Cosmed Group operates the equipment that we construct; our customers benefit from the refinements driven into our technologies through practical, hands on experience. Our designs incorporate a practical approach, innovative process control and a focus on regulatory expectations.
Comed Diversity
Cosmed Group’s line of pasteurization and sterilization equipment evolved through our long history providing contract services. Cosmed Group operates the equipment that we construct; our customers benefit from the refinements driven into our technologies through practical, hands on experience. Our designs incorporate a practical approach, innovative process control and a focus on regulatory expectations.
EtO Sterilizers
H2O Express Steam Pasteurizers
PPO Pasteurizers
Process Automation
Scrubbers and Environmental Controls
Advanced Desktop Spirometer with spirometry, airway resistance and respiratory mechanics
Comed Diversity Program
- Pony FX is the new generation of desktop spirometers developed by COSMED for complete spirometry (FVC/SVC, MVV, bronchial provocation) and respiratory mechanics (MIP/MEP, Rocc) testing. With a large colour LCD screen and inbuilt thermal printer, it is possible to perform tests without the need of a computer.
The Pony FX has internal memory, which can store many patients/tests, and comes with a powerful and user-friendly PC software (OMNIA) for data management and real-time PC testing.
Pony FX is configured with an accurate and reliable bidirectional digital turbine flowmeter.
Additional optional tests include: Airway Resistance (Rocc) and Pulseoximetry (SpO2).
Two different Pony FX models are currently available:- Pony FX: desktop spirometer with COSMED validated digital bidirectional turbine flowmeter.
- Pony FX MIP/MEP: desktop spirometer for basic spirometry tests and respiratory mechanics measurements (MIP/MEP).
- Desktop spirometry family. The 4th generation of the most sold desktop spirometer is available with two models Pony FX and Pony FX MIP/MEP.
Standalone use. Compact desktop device with internal rechargeable battery, a large LCD screen and in-built thermal printer that allow testing without a computer or mains power lead.
Powered by OMNIA. OMNIA allows intuitive, immediate spirometry testing with advanced text interpretation and graphical tools for quick assessment. Includes new standards and predicteds according to latest ATS/ERS guidelines (2005 Consensus, GLI, etc).
Pediatric Incentivation. Possibility to perform spirometry test with a selection of innovative pediatric incentivation graphics with user defined effort grade on both volume and flow (both PEF and FVC predicteds).
Additional PFT test features. Spirometry tests with Pony FX can be complemented with additional tests like respiratory mechanics (MIP/MEP), respiratory resistance (Rocc), integrated pulseoximeter (SpO2).
Validated Digital Turbine Flowmeter. Independently validated turbine flowmeter by LDS Hospital using the ATS 24 standard volume-time waveforms (Crapo R. O. 2004 “Validation of COSMED turbine vs ATS 24 standard volume-time waveforms“). Pony FX
Advanced desktop spirometer with spirometry and airway resistance- Full spirometry testing (FVC, SVC, MVV, Pre/Post BD)
- Airway resistance by Occlusion Technique (option)
- Pulseoximetry with integrated high quality SpO2 monitor (option)
- Colour LCD display with real time graphs and embedded high speed Thermal Printer
- Turbine flowmeter fully complies with ATS standards
- Provided with OMNIA software for data management, real time testing and interpretation on PC
Pony FX MIP/MEP
Advanced desktop spirometer with spirometry and respiratory mechanics- Full spirometry testing (FVC, SVC, MVV, Pre/Post BD)
- Respiratory Mechanics MIP/MEP
- Airway resistance by Occlusion Technique (option)
- Oxygen Saturimetry with integrated SpO2 monitor (option)
- Colour LCD display with real time graphs and embedded high speed Thermal Printer
- Available with COSMED turbine flowmeter
- Provided with OMNIA software for data management, real time testing and interpretation on PC
Note: ⚫ Standard ⚪ OptionMAIN PARAMETERS Pony FX Pony FX MIP MEP Spirometry (FVC, SVC, MVV, Broncho-challenge) ⚫ ⚫ Respiratory Mechanics (MIP/MEP) ⚪ ⚫ Pulse Oximetry (SpO2, HR) ⚪ ⚪ Airway Resistance (Rocc, Rint, Gocc) ⚪ HARDWARE Flowmeter Bidirectional turbine 0-28mm Display Colour LCD 320 x 240 pixel Printer High speed thermal printer Battery Rechargeable Li-ion Internal Memory Yes Interface ports USB A-B, RS-232, HR-TTL, Flowmeter Electrical requirements 100-240V ± 10% 50/60 Hz SOFTWARE Software Interface OMNIA (click here) OS Compatibility Windows 7, 8, 8.1, 10 Available languages Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Turkish, Russian, Chinese Traditional & Simplified, Korean, Romanian, Polish, Czech, Norwegian, Hebrew Rocc
The Rocc module for measurement of airway resistance in children and uncooperative patients- Interrupter technique (Rrs, int)
- High reproducibility and correlation with body plethysmography tests
- Ideal for testing non collaborative, critically ill patients and children
- Simplified test manoeuvre
- Easy to disinfect
- Scientifically validated
Pulseoximeter
High quality Pulse Oximeters for integrated oxygen saturimetry during rest or stress testing- Full range of oximeters and sensors for different patient applications
- Small, lightweight and portable technology
- Low power draw (60 mW)
- Accurate performance in challenging monitoring environments at critical SpO2 levels
- Intelligent pulse-by-pulse filtering
Antiviral and antibacterial respiratory filters
An easy way to ensure protection from cross-contamination which keeps both the patient and operator safe without compromising on system performance.
Two mouthpiece types, oval and round, guarantee the maximum ergonomics and thecompatibility with any equipment connector.- High viral and bacterial filtration efficiency (99.999%)
- Low resistance to airflow
- Suitable for both lung function and exercise testing
- Minimal deadspace
- Individually packaged in 50 pieces box
These filters comply with latest ERS guidelines recommending to use the filters with minimum proven efficiency for high expiratory flow of 600 to 700 L/min.Calibration syringe
The simplest and most reliable accuracy check of flow volume measurement- Certified 3 liter alluminium calibration syringe
- Accuracy: ±1/2 of 1% full scale
- Adjustable stops for additional smaller stroke volumes
- 100% leak tested
- Calibration standard according to ATS/ERS Guidelines
- div > .uk-panel', row:true}'>
Software Printout (Spirometry)
Thermal Printout (Spirometry)
USB Printer A4 Printout (Spirometry)